Field Density Test by Water Replacement Method

Field Density Test by Water Replacement Method

Water replacement method is used for determination of field compaction or field density of soil and gravely fills. The method is used for soil fills containing particles larger than 75 mm such as earth embankments, road fills, or structural backfills. The test method is standardized per ASTM D5030. As I’ve explained in my earlier posts … Read more

Standard Proctor Test – Procedure – Apparatus – Calculation

Standard Proctor Test

Maximum dry Density of soil is determined in the laboratory with the help of Standard Proctor Test standardized by ASTM D698 and AASHTO T99. So this read explains in depth, the significance, background, apparatus and procedure of the standard proctor test. Basics of Soil Compaction It is worth mentioning, that densification or compaction of soil … Read more